Module Level Firefighter Safety Switches
● Firefighter Satety Switch for Solar System.
● Over temperature protection.
● Plug and play easy installation.
● IP66 aluminum durable enclosure.
● Emergency button for 100% disconnect.
● Firefighter Satety Switch for Solar System.
● Over temperature protection.
● Plug and play easy installation.
● IP66 aluminum durable enclosure.
● Emergency button for 100% disconnect.
YRO Rapid Shutdown is a DC-breaking device used in photovoltaic system, it can limit the electric range and even DC voltage. To guarantee the safe of firefighters in the process of fire fighting and rescue of facilities installed with photovoltaic power generation system, and has no risk of electric shock.
High Craftsmanship and Standards
Technical Data
Type |
YRSD-1P |
YRSD-2P |
Number of PV Inputs |
1 |
2 |
Number of Modules Recommend |
1-2 |
2-4 |
Maximum Allowed Input Voltage |
120V |
|
Maximum Allowed Input Current |
18A / 25A |
|
Maximum Output Volt age |
120V |
240V |
System Volt age |
1000V / 1500V |
|
Control Compliance |
24VDC + 2 x 0.8mm2 Cable |
|
Control Requirements |
21.6V~26.4V at nomi. 27~36mA/unit |
|
Ambient Operating Temperature |
-30°C to +60°C |
|
Protection Temperature |
85°C |
|
IP Level |
>IP68, NEMA 4X |
|
Fire-proof Level |
Flame retardant, UL94-V0 |
|
Humidity |
0%~90% |
|
PV Connectors |
Connector (Customized) |
|
Design Life Span |
25 years |
|
Size |
155.8*73.7*30.2 |
155.8*73.7*30.2 |
Weight |
< 200g (Excluding Cables) |
|
Cable Length, PV1+ Input |
300mm |
300mm |
Cable Length, PV1- Input |
300mm |
300mm |
Cable Length, PV2+ Input |
/ |
300mm |
Cable Length, PV2- Input |
/ |
300mm |
Cable Length, Power Out put |
1800mm |
1800mm |
Cable Length, 24Vdc Control Cable |
1800mm |
1800mm |
andard Comliance |
NEC2017/2020 (690.12); UL1741; UL3741; IEC/EN62109; IEC/EN61000 |
Summary
The YRO Modular level RSD DC 24V Series Overview is designed to be installed at solar panel level and providessafety shutdown of the DC supply to ZERO VOLTS in case of emergency.Shutdown is initiated in 3 ways -ManualOperation,AC Supply Cut-Off or Temperature Rise Trigger as follows:
YRSD-1P 1-to-1 wiring
Not: For NEC 2017 /2010 compliance PV panels should be <40v for 2-to-1 wiringand > =40v for 1-to-1 wiring (For YRSD -1P)
YRSD-2P 2-to-1 wiring
YRSD-1P/2P Series
Dimension
Technical Specification
Model |
YRSD-CB |
Operating AC Voltage Range |
100V-240V |
Nominal Frequency |
50/60 Hz |
Output Voltage |
24V DC |
Output Current/Power |
2.2A/50W |
24Vdc Control Cable Size |
0.823 mm2/18 AWG |
24Vdc Control Cable Length With Standard Connectors |
20 m / 30 m /100 m |
Spare Terminal Connectors |
Yes |
Maximum YRSD-1P |
60 Units |
Maximum YRSD-2P |
30 Units |
Dimensions (mm) |
250*210*210 |
Lockable |
Optional (IP54) |
Operating Temperature Range |
-30°C~+70°C(50°C No degradation) |
Protection Class |
IP65 |
Mounting |
Wall Mounted |
Maximum Distance (Last RSD to Controller Box) |
200m |
Parallel connection of multiple control boxes
Time: April 7-9, 2025Location: Dubai World Trade Center (DWTC)Booth: H8.A32At the 2025 Dubai Energy Exhibition, YueqingYiruiElectricApplianceCo.,Ltd., through the do...
A sudden power outage not only disrupts household activities but can also pose serious risks, such as jeopardizing the power supply for medical equipment or causing ...
In an era where digitalization and intelligence are deeply integrated, power system management is undergoing a revolutionary transformation. Traditional manual switc...
The air conditioner at home suddenly stopped working, and all the lights flickered and then went out behind this seemingly ordinary tripping phenomenon, in fact, the...