Module Level Firefighter Safety Switch

Module RSD Controller Rapid Shutdown YRSD-P-PLC
Module RSD Controller Rapid Shutdown YRSD-P-PLC

Module RSD Controller Rapid Shutdown YRSD-P-PLC

● Firefighter Satety Switch for Solar System.

● Over temperature protection.

● Plug and play easy installation.

● IP66 aluminum durable enclosure.

● Emergency button for 100% disconnect.

Product Description

The 2017 National Electrical Code (NEC) Section 690.12 requires the module-level rapid shutdown of solar systems, all conductors within an array’s 1-ft boundary have to be reduced to 80V or less within 30 seconds of rapid shutdown initiation.

 

High Craftsmanship and Standards

 

Technical Data

Type

YRSD-1P

YRSD-2P

Number of PV Inputs

1

2

Number of Modules Recommend

1-2

2-4

Maximum Allowed Input Voltage

120V

Maximum Allowed Input Current

18A / 25A

Maximum Output Volt age

120V

240V

System Volt age

1000V / 1500V

Control Compliance

24VDC + 2 x 0.8mm2 Cable

Control Requirements

21.6V~26.4V at nomi. 27~36mA/unit

Ambient Operating Temperature

-30°C to +60°C

Protection Temperature

85°C

IP Level

>IP68, NEMA 4X

Fire-proof Level

Flame retardant, UL94-V0

Humidity

0%~90%

PV Connectors

Connector (Customized)

Design Life Span

25 years

Size

155.8*73.7*30.2

155.8*73.7*30.2

Weight

< 200g (Excluding Cables)

Cable Length, PV1+ Input

300mm

300mm

Cable Length, PV1- Input

300mm

300mm

Cable Length, PV2+ Input

/

300mm

Cable Length, PV2- Input

/

300mm

Cable Length, Power Out put

1800mm

1800mm

Cable Length, 24Vdc Control Cable

1800mm

1800mm

andard Comliance

NEC2017/2020 (690.12); UL1741; UL3741; IEC/EN62109; IEC/EN61000

 

YRSD Modular level PLC type
The YRSD Modular level PLC type is designed to be installed at solar panel level and provides safety shutdown ofthe DC supply to ZERO vOLTS in case of emergency. Shutdown is initiated in 4 ways - Manual Operation, ACSupply Cut-Off or Temperature Rise Trigger sunspec lnverter as follows:

 

YRSD-1P
when the open-circuit voltage of PV panel is below 120V.

 

YRSD-2P
when the open-circuit voltage of Pv panel is below 120v.

 

 


 

Message

Related products

Emergency Button Switch Firefighter safety PLC type

Emergency Button Switch Firefighter safety PLC type

Click to Learn More

Solar Module Level Rapid Shutdown YRSD-P

Solar Module Level Rapid Shutdown YRSD-P

Click to Learn More

Module Level Quick Shutdown Device YRSD-P

Module Level Quick Shutdown Device YRSD-P

Click to Learn More

Related News

> What is the Difference Between MTS and ATS?

Automatic Transfer Switches (ATS) and Manual Transfer Switches (MTS) are essential devices in electrical systems for power source switching. They each have unique op...

> What Are the Consequences of ATS Transfer Failures?

In today's world, which is highly dependent on electric power, the Automatic Transfer Switch (ATS)plays a crucial role in ensuring the continuity and reliability of ...

> What is the Working Principle of an ATS?

In today's fast paced world, electricity flows through the veins of modern cities, powering industries, businesses, and daily activities. However, with the everprese...

> What Is a Fire Safety Switch?

In daily life and industrial production, fire safety is always an important issue that we cannot ignore. As an important part of the fire protection system, fire saf...

We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All