YRSP-D2 B + C is a Typel +2 surge protector specially designed for photovoltaic power generationjt is installed at the out let of photovoltaic panels with high risk of direct lighting strike, it is suitable for photovoltaic system protection with DC voltages of 1000V and 1500V.
Fuatures
Type 1 +2 surge protective device for Photovoltaic
Uc to 1 500VDC
Impulse currents limp/ltotal: 5/20卩s & 10/350ps
Common and different mode protection
Remote Signaling(option)
No leakage, no operating currents
Plug-in modules
EN 61643-31
Specifications:
Model
YRSP-D2
Description
Type 1 +2 PV DC surge protector
Poles
2P
3P
3P
Protection mode
CM/DM
Max. operating voltage
Ucpv
600 Vdc
1000 Vdc
1500 Vdc
Current withstand short-circuft
Iscpv
1000A
Operating current - to the voltage Ucpv
lepv
none
Leakage current - to the voltage Ucpv
Ipe
none
Follow current
If
none
Nominal discharge current -8/20 ps
In
20 KA
Max discharge current by pole - 8/20 ps
Imax
50 KA
Max. Lightning current by pole - 10/350 ps
limp
6.25KA
Total lightning cure nt - 10/350 卩 s
Itotal
12.5KA
Total Maximal discharge current - 8/20 卩s
Itotal
60 KA
Protection level CM/DM (at In)
Up
2.2 KV
3.5 KV
5.2 KV
Mechanical characteristics
Dimensions
See diagram
Connection
Screw terminal for 2.5-25 mm2 wire
Disconnection indie ator
1 mechanical indicator by pole
Remote signaling
Option YRSP-D2 - Output on changeover contact
Mounting
Symmetrical rail 35 mm(EN60715)
Operating temperature
-40°C ~+85°C
Protection class
IP20
Housing material
Thermoplastic UL94-V0
Standards compliance
EN50539-11/IEL61643-31
Message
Related products
WiFi Circuit Breaker/2P
Click to Learn More
WiFi Circuit Breaker/1P
Click to Learn More
Solar Electric PV T2 DC Surge Protective Device YRSP-D2
In daily life and industrial production, fire safety is always an important issue that we cannot ignore. As an important part of the fire protection system, fire saf...
In modern power systems, the Automatic Transfer Switch (ATS) is a critical device for ensuring uninterrupted power supply. It is widely used in essential locations s...
In the gentle mountain breeze, YRO's office team gathered at the base of a scenic peak, ready to embark on an unforgettable team building hike. Anticipation and exci...
In electrical systems, the isolator switch serves as a crucial device for disconnecting circuits, playing a vital role in ensuring the safety of both systems and per...
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.